The duty cycle (DC) is the proportion of time during which a motor or drive system runs under load within a work cycle, expressed as a percentage. It is a decisive factor for the thermal load on motors, bearings, and screw drives. The higher the duty cycle, the less time remains for cooling.

How is the duty cycle calculated?

ED=tLast/(tLast+tPause)·100ED = t_{Last} / (t_{Last} + t_{Pause}) · 100 %

EDED = Duty cycle [%]
tLoadt_{Last} = Running time under load within a cycle [ss]
tPauset_{Pause} = Pause or standstill time within a cycle [ss]

Example: An axis travels for 30 s and then remains stationary for 90 s. DC=30/(30+90)·100%=25%DC = 30 \,/\, (30 + 90)\, ·\, 100\, \% = 25 \,\%.

For electric motors, this corresponds to intermittent periodic duty (duty type S3), for which manufacturers specify performance data at fixed DC values.

Why is the duty cycle important?

Thermal stress

Long running times without pauses lead to overheating

Service life

Exceeding the rated DC significantly shortens the service life

Power sizing

DC determines the choice of motors, bearings, and gearboxes

Implications for Threaded Drives

For trapezoidal screws, the duty cycle directly limits the permissible load due to frictional heat. Ball screws are suitable for high duty cycles, but heating affects accuracy and preload. Details on design can be found under duty cycle of the ball screw. Together with the running time per day, the DC is factored into the service life in operating hours.